Background:
We have received feedback from a customer regarding the documentation of Temperature Sensitive Storage Efficiency (TSSE) on AFF-C series platforms running ONTAP 9.16.1P7.
Summary of Customer Feedback:
The customer observed that when a volume is thick-provisioned, the TSSE scanner appears to run, but no compression or deduplication actually occurs.
The storage efficiency ratio remains 1:1, and there is no data reduction, which is consistent with the ONTAP design.
However, the customer pointed out that:
• There is no clear, explicit statement in the current public documentation or KB articles that TSSE does not perform compression or deduplication on thick-provisioned volumes.
• The current documentation could lead to a misunderstanding, as it does not clearly differentiate the behavior between thin- and thick-provisioned volumes regarding TSSE.
• The customer requests that the documentation explicitly state that:
o TSSE only works on thin-provisioned volumes.
o Thick-provisioned volumes are not eligible for TSSE.
o On thick-provisioned volumes, the TSSE scanner may appear to run, but no compression or deduplication is performed, and the efficiency ratio remains 1:1.

References:
• ONTAP Documentation: Temperature-sensitive storage efficiency
https://docs.netapp.com/us-en/ontap/volumes/enable-temperature-sensitive-efficiency-concept.html

• KB: How to disable TSSE in ONTAP 9.8 and later 
https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/How_to_disable_TSSE_in_the_ONTAP_9.8
※Regarding the KB, I’ve just added the following from my side for now:

>Thick provisioned volumes are not eligible for TSSE.
>TSSE only works on thin-provisioned volumes.

Current Documentation Excerpts:
• The above documentation and KBs mention TSSE is enabled for new volumes on AFF platforms and cannot be disabled on AFF-C series, but do not clearly state the limitation regarding thick-provisioned volumes.

Customer’s Request:
The customer has specifically requested that the documentation be updated to explicitly clarify the above points, to prevent further confusion for users.

Request for Documentation Update:
Please review and update the relevant ONTAP public documentation and KB articles to include the following clarifications:

  1. TSSE only applies to thin-provisioned volumes.
  2. Thick-provisioned volumes are not eligible for TSSE.
  3. On thick-provisioned volumes, although the TSSE scanner may appear to operate, no compression or deduplication is performed, and the efficiency ratio remains 1:1.
  4. This is by design in ONTAP, and is not a defect.

Impact:
The lack of clear documentation has led to repeated customer inquiries and confusion regarding the expected behavior of TSSE on thick-provisioned volumes.
Addressing this will improve customer experience and reduce support cases on this topic.

Thank you for your attention to this matter.

Public issues must not contain sensitive information

  • This issue contains no sensitive information.

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions